Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
The Korean Journal of Internal Medicine ; : 176-184, 2018.
Artigo em Inglês | WPRIM | ID: wpr-919001

RESUMO

BACKGROUND/AIMS@#Procalcitonin (PCT) may prove to be a useful marker to exclude or predict bloodstream infection (BSI). However, the ability of PCT levels to differentiate BSI from non-BSI episodes has not been evaluated in nosocomial BSI.@*METHODS@#We retrospectively reviewed the medical records of patients ≥ 18 years of age with suspected BSI that developed more than 48 hours after admission.@*RESULTS@#Of the 785 included patients, 105 (13.4%) had BSI episodes and 680 (86.6%) had non-BSI episodes. The median serum PCT level was elevated in patients with BSI as compared with those without BSI (0.65 ng/mL vs. 0.22 ng/mL, p = 0.001). The optimal PCT cut-off value of BSI was 0.27 ng/mL, with a corresponding sensitivity of 74.6% (95% confidence interval [CI], 66.4% to 81.7%) and a specificity of 56.5% (95% CI, 52.7% to 60.2%). The area under curve of PCT (0.692) was significantly larger than that of C-reactive protein (CRP; 0.526) or white blood cell (WBC) count (0.518). However, at the optimal cut-off value, PCT failed to predict BSI in 28 of 105 cases (26.7%). The PCT level was significantly higher in patients with an eGFR < 60 mL/min/1.73 m² than in those with an eGFR ≥ 60 mL/min/1.73 m² (0.68 vs. 0.17, p = 0.01).@*CONCLUSIONS@#PCT was more useful for predicting nosocomial BSI than CRP or WBC count. However, the diagnostic accuracy of predicting BSI remains inadequate. Thus, PCT is not recommended as a single diagnostic tool to avoid taking blood cultures in the nosocomial setting.

2.
The Ewha Medical Journal ; : 69-75, 2016.
Artigo em Inglês | WPRIM | ID: wpr-89019

RESUMO

OBJECTIVES: To assess the current state of anemia evaluation in the elderly over 80 years of age. METHODS: Patients who were more than 80 years old and visited Dongguk University Ilsan Hospital from April 2005 to February 2014 were included. Statistical analysis were assessed using the logistic regression model. RESULTS: Total 548 patients, who had anemia according to WHO criteria, were identified. The median age was 85 years old (range, 82 to 99 years) and median hemoglobin level was 11.0 g/dL (range, 2.7 to 12.9 g/dL). Twenty-eight, 468, and 52 patients were classified as microcytic anemia, normocytic anemia, and macrocytic anemia, respectively. Among them, 397 patients (72.4%) did not undergo proper evaluation for the cause anemia i.e., 8 cases (28.5%) of microcytic anemia, 361 cases (77.1%) of normocytic anemia, and the 28 cases (53.84%) of 52 macrocytic anemia patients. The remaining 151 patients (27.6%) had completed the evaluation, and 24 patients (15.9%) were diagnosed as solid malignancies. In the assessment of iron deficiency anemia, hemoglobin levels, and age had no effect on whether or not to perform esophagogastroduodenoscopy. CONCLUSION: This finding showed that physicians often neglected anemia in individuals over 80 years of age. Though these patients have limited life expectancy, physicians should carefully discriminate the sub-population who will be benefit from adequate evaluation and treatment.


Assuntos
Idoso , Humanos , Anemia , Anemia Ferropriva , Anemia Macrocítica , Endoscopia do Sistema Digestório , Expectativa de Vida , Modelos Logísticos
3.
Journal of Laboratory Medicine and Quality Assurance ; : 214-224, 2016.
Artigo em Coreano | WPRIM | ID: wpr-65273

RESUMO

As the Immunoserology Subcommittee of the Korean Association of External Quality Assessment, we organized two trials on the external quality assessment of viral markers and serological tests for syphilis (STS) in 2015. For this purpose, we delivered three kinds of pooled sera specimens for external proficiency testing to 1,071 and 1,074 institutions for the first and second trials, respectively. Pooled sera were checked for their homogeneity and stability using multiple methods between the day of their manufacture and three days after dispatching. The number of participating laboratories was 1,055 (98.5%) and 1,055 (98.2%) in the first and second trial, respectively. The most commonly tested items were hepatitis B surface antigen, followed by the antibodies to hepatitis B surface antigen, antihuman immunodeficiency virus, anti-hepatitis C virus, STS, and anti-hepatitis B core. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay (CLIA) and the electrochemiluminescence immunoassay, which were found to generate few false positive results. In contrast, false negative results were frequently found when the immunochromatographic assay (ICA) was used; the use of ICA for detecting viral markers has been steadily increasing in recent years. Furthermore, the use of turbidoimmunoassay and CLIA, tests recently introduced for the measurement of nontreponemal and treponemal antibodies, is also increasing.


Assuntos
Anticorpos , Biomarcadores , Hepatite B , Antígenos de Superfície da Hepatite B , Hepatite C , HIV , Imunoensaio , Cromatografia de Afinidade , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Luminescência , Testes Sorológicos , Sífilis
4.
Annals of Laboratory Medicine ; : 23-27, 2016.
Artigo em Inglês | WPRIM | ID: wpr-37154

RESUMO

BACKGROUND: Automated Mediace Treponema pallidum latex agglutination (TPLA) and Mediace rapid plasma reagin (RPR) assays are used by many laboratories for syphilis diagnosis. This study compared the results of the traditional syphilis screening algorithm and a reverse algorithm using automated Mediace RPR or Mediace TPLA as first-line screening assays in subjects undergoing a health checkup. METHODS: Samples from 24,681 persons were included in this study. We routinely performed Mediace RPR and Mediace TPLA simultaneously. Results were analyzed according to both the traditional algorithm and reverse algorithm. Samples with discordant results on the reverse algorithm (e.g., positive Mediace TPLA, negative Mediace RPR) were tested with Treponema pallidum particle agglutination (TPPA). RESULTS: Among the 24,681 samples, 30 (0.1%) were found positive by traditional screening, and 190 (0.8%) by reverse screening. The identified syphilis rate and overall false-positive rate according to the traditional algorithm were lower than those according to the reverse algorithm (0.07% and 0.05% vs. 0.64% and 0.13%, respectively). A total of 173 discordant samples were tested with TPPA by using the reverse algorithm, of which 140 (80.9%) were TPPA positive. CONCLUSIONS: Despite the increased false-positive results in populations with a low prevalence of syphilis, the reverse algorithm detected 140 samples with treponemal antibody that went undetected by the traditional algorithm. The reverse algorithm using Mediace TPLA as a screening test is more sensitive for the detection of syphilis.


Assuntos
Humanos , Algoritmos , Antibacterianos/uso terapêutico , Testes de Fixação do Látex , Reaginas/sangue , Sífilis/diagnóstico , Treponema pallidum/isolamento & purificação
5.
Journal of Laboratory Medicine and Quality Assurance ; : 124-133, 2015.
Artigo em Coreano | WPRIM | ID: wpr-189315

RESUMO

As Immunoserology Subcommittee of the Korean Association of External Quality Assessment Service, we organized two trials on the external quality assessment of viral markers and serological tests for syphilis (STS) in 2014. For this purpose, we delivered three kinds of pooled sera specimens for external proficiency testing to 1,060 and 1,064 institutions for the first and second trials, respectively. Pooled sera were checked for their homogeneity and stability by using more than three other methods between the day of their manufacture and 3 days after despatching. The numbers of participating laboratories were 1,053 (99.3%) and 1,046 (99.3%) in the first and second trials, respectively. The most commonly tested items were hepatitis B surface antigen, followed by antibody to hepatitis B surface antigen, anti-human immunodeficiency virus, anti-hepatitis C virus, STS, and anti-hepatitis B core. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay (CLIA) and the electrochemiluminescence immunoassay, which generated few false positive results. In contrast, false negative results were frequently found through the immunochromatography assay, the use of which for detecting viral markers has been steadily increasing in recent years. Furthermore, the use of turbidoimmunoassay and CLIA, which are new tests recently introduced for the measurement of non-treponemal and treponemal antibodies, is also increasing.


Assuntos
Anticorpos , Biomarcadores , Hepatite B , Antígenos de Superfície da Hepatite B , Hepatite C , HIV , Imunoensaio , Cromatografia de Afinidade , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Luminescência , Testes Sorológicos , Sífilis
6.
Blood Research ; : 184-185, 2015.
Artigo em Inglês | WPRIM | ID: wpr-36723

RESUMO

No abstract available.


Assuntos
Linfocitose , Linfócitos T , Timoma
7.
Laboratory Medicine Online ; : 36-42, 2014.
Artigo em Coreano | WPRIM | ID: wpr-82414

RESUMO

BACKGROUND: Establishment of a national reference panel for syphilis antibodies is necessary to evaluate the performance of in-vitro diagnostic tests for syphilis and to verify test quality. This study aimed to establish a national reference panel for syphilis antibodies, to assess the suitability of a panel for non-treponemal and treponemal testing, and to assess the reactivity of the various tests currently in use. METHODS: Treponemal pallidum particle agglutination (TPPA)-positive and -negative fresh frozen plasma samples were obtained. After the fresh frozen plasma was converted to serum by defibrination, the samples were pooled. Two candidate reference standards containing no syphilis antibodies and 10 candidate reference standards containing syphilis antibodies were prepared on the basis of reactivity in the TPPA assay. Candidate reference standards were tested by three laboratories using five non-treponemal tests and four treponemal tests. RESULTS: All three laboratories reported positive non-treponemal test results for the mixed-titer performance panel (MP)/6-MP/12. MP/1, MP/2, and MP/3 were negative for non-treponemal tests. MP/4 and MP/5 were reported either as positive or negative according to the laboratories. All laboratories reported positive TPPA results for MP/3-MP/12 and negative results for MP/1 and MP/2. No significant difference was detected among the treponemal testing results in three laboratories. CONCLUSIONS: We established 12 candidate national reference standards containing various concentrations of syphilis antibodies. A collaborative study using nine tests demonstrated that 12 candidate national reference standards presented consistent results, except a few assays with low sensitivity, and thus could be used as a national reference panel for syphilis antibody testing.


Assuntos
Aglutinação , Anticorpos , Testes Diagnósticos de Rotina , Coreia (Geográfico) , Plasma , Sífilis
8.
Journal of Laboratory Medicine and Quality Assurance ; : 161-170, 2014.
Artigo em Coreano | WPRIM | ID: wpr-60461

RESUMO

We performed two trials on the external quality assessment of viral markers and serological tests for syphilis (STS) organised by the Immunoserology Subcommittee of the Korean Association of Quality Assurance for Clinical Laboratories in 2013. In each trial, we delivered 3 kinds of pooled sera specimens to 1,021 institutions for external proficiency testing. Pooled sera were checked for their homogeneity and stability by using more than 3 other methods between the day of their manufacture and 3 days after despatching. The numbers of participating laboratories were 1,019 (99.8%) and 1,020 (99.8%) for the first and second trials, respectively. The most commonly tested items were hepatitis B surface antigen followed by antibody to hepatitis B surface antigen, anti-human immunodeficiency virus, anti-hepatitis C virus, STS, and anti-hepatitis B core. The most frequently used methods for detecting viral markers were the chemiluminescence immunoassay (CLIA) and the electrochemiluminescence immunoassay, which generated a few false positive results. In contrast, false negative results were frequently found through the immunochromatography assay, the use of which for detecting viral markers has been steadily increasing in recent years. The new tests, turbidoimmunoassay and CLIA, have recently been introduced for the measurement of non-treponemal and treponemal antibodies, and their use is also increasing.


Assuntos
Anticorpos , Biomarcadores , Hepatite B , Antígenos de Superfície da Hepatite B , Hepatite C , HIV , Imunoensaio , Cromatografia de Afinidade , Coreia (Geográfico) , Ensaio de Proficiência Laboratorial , Luminescência , Testes Sorológicos , Sífilis
10.
Allergy, Asthma & Immunology Research ; : 337-339, 2013.
Artigo em Inglês | WPRIM | ID: wpr-48228

RESUMO

A fixed drug eruption (FDE) is not difficult to diagnose, given its clinical characteristics. However, the causative agent can be difficult to identify, particularly when the patient denies ingestion of any drugs. To the best of our knowledge, we present herein the first reported case of an FDE caused by antibiotics taken in food; doxycycline and erythromycin contained in pork and fish. A 57-year-old female experienced repeated episodes of well-demarcated erythematous patches covering her entire body. She denied taking any medications, but she thought that the lesions appeared after consuming pork and/or fish. An oral provocation test showed positive results for doxycycline and erythromycin, commonly used antibiotics in live-stock farming and in the fishing industry. Because of the antibiotics' thermostability, cooking does not guarantee the elimination of residual drugs. From the patient's history, we concluded that doxycycline and erythromycin contained in the pork and fish that she ate were the cause of the FDE.


Assuntos
Feminino , Humanos , Antibacterianos , Culinária , Doxiciclina , Toxidermias , Ingestão de Alimentos , Eritromicina
11.
Annals of Laboratory Medicine ; : 407-412, 2012.
Artigo em Inglês | WPRIM | ID: wpr-13496

RESUMO

BACKGROUND: We compared the LightCycler MRSA advanced test (Roche Diagnostics, Germany) with enrichment culture methods to evaluate the relative diagnostic performance of the LightCycler MRSA advanced test for active surveillance in a high-prevalence setting. METHODS: A total of 342 nasal swab specimens were obtained from patients in the intensive care unit at admission and on the seventh day for follow-up. The results of LightCycler MRSA advanced test were compared to those of the enrichment culture. For discrepant results, mecA gene PCR was performed. RESULTS: For the detection of methicillin-resistant Staphylococcus aureus (MRSA), the LightCycler MRSA advanced test showed 98.5% sensitivity and 78.6% specificity and had positive and negative predictive values of 75.0% and 98.8%, respectively. A total of 46 samples had discrepant results between the LightCycler MRSA advanced test and enrichment culture. Of the 44 specimens that were positive in the LightCycler MRSA advanced test but negative by enrichment culture, mecA genes were detected in 37 specimens. In addition, of the original 44 cases, 21 patients had a history of MRSA colonization or infection within the last month; of those 21 specimens, 20 were positive for mecA gene as shown by PCR. Seven mecA-negative discrepant specimens comprised 3 methicillin-sensitive S. aureus-culture positive and only 2 patients had MRSA infections. CONCLUSIONS: Despite its low specificity and positive predictive value, the LightCycler MRSA advanced test could serve as a rapid test for patients colonized with MRSA.

12.
Infection and Chemotherapy ; : 481-484, 2012.
Artigo em Coreano | WPRIM | ID: wpr-130669

RESUMO

Arcanobacterium haemolyticum is a gram-positive bacillus that is most commonly implicated in pharyngitis and infections of the skin and soft tissue. Systemic and deep-seated infections caused by this organism are rarely reported in the literature. Recently, we encountered two cases of invasive infections caused by A. haemolyticum. We describe two cases, one with vertebral osteomyelitis with an epidural abscess and the other with a buttock abscess with bacteremia.


Assuntos
Adulto , Humanos , Abscesso , Arcanobacterium , Bacillus , Bacteriemia , Nádegas , Abscesso Epidural , Osteomielite , Faringite , Pele
13.
Journal of Clinical Neurology ; : 203-209, 2011.
Artigo em Inglês | WPRIM | ID: wpr-163266

RESUMO

BACKGROUND AND PURPOSE: Remnant lipoproteins (RLPs) are products of partially catabolized chylomicrons and very-low-density lipoprotein, from which some triglycerides have been removed. These particles are smaller and denser than the parent particles and are believed to be strongly atherogenic. We explored the association between RLP cholesterol (RLP-C) and ischemic stroke, including stroke subtypes. METHODS: A cohort of 142 ischemic stroke patients (90 men and 52 women; age, 65.2+/-12.8 years, mean+/-SD) was enrolled; all had acute infarcts confirmed by diffusion-weighted MRI, and had fasting lipograms. A full stroke-related evaluation was conducted on each patient. An outpatient population of 88 subjects without a history of cerebrovascular or cardiovascular disease served as a control group. Serum RLP fractions were isolated using an immunoaffinity gel containing specific antiapolipoprotein (anti-apo)B-100 and anti-apoA-I antibodies. RLP-C values were considered to be high when they were in the highest quartile of all values in the study. RESULTS: High RLP-C values were more common in stroke patients than in control patients (31.0% vs. 14.8%, p=0.01), when 5.6 mg/dL (>75th percentile) was used as the cutoff value. Multivariable analyses indicated that RLP-C was a risk factor for stroke, with an odds ratio of 2.54 (p=0.045). The RLP-C level was higher in the large artery atherosclerosis subgroup (5.7+/-3.9 mg/dL) than in any other stroke subgroup (small vessel occlusion, 4.9+/-5.9 mg/dL; cardioembolism, 1.8+/-2.3 mg/dL; stroke of undetermined etiology, 3.1+/-2.9 mg/dL). CONCLUSIONS: We have found an association between high RLP-C levels and ischemic stroke, and in particular large artery atherosclerotic stroke.


Assuntos
Humanos , Masculino , Anticorpos , Artérias , Aterosclerose , Doenças Cardiovasculares , Colesterol , Quilomícrons , Estudos de Coortes , Jejum , Glicosaminoglicanos , Lipoproteínas , Razão de Chances , Pacientes Ambulatoriais , Pais , Fatores de Risco , Acidente Vascular Cerebral , Triglicerídeos
14.
Korean Journal of Clinical Microbiology ; : 74-78, 2011.
Artigo em Coreano | WPRIM | ID: wpr-123823

RESUMO

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a major nasocomial pathogen. The active surveillance of MRSA is essential to limit its transmission. The BD GeneOhm MRSA real-time PCR assay (Becton Dickinson Diagnostics, San Diego, USA) has been recently developed and used for same-day MRSA detection directly from nasal swab specimens. The authors of the present study compared GeneOhm MRSA PCR with culture methods to evaluate its diagnostic performance for MRSA active surveillance. METHODS: The present study was conducted on patients admitted to the ICU for six months. A total of 371 nasal swab specimens were obtained from patients at admission day and at the seven-day follow-up. The swab was streaked onto culture media, and presumptive S. aureus colonies were confirmed as MRSA using the BD Phoenix automated microbiology system (Becton Dickinson Diagnostic Systems, Sparks, USA). In addition, GeneOhm MRSA PCR was performed. For discrepant results between Gene-Ohm MRSA PCR and culture, the enrichment broth culture method was performed. RESULTS: There were 34 samples with discrepant results between the GeneOhm MRSA PCR and culture. The overall agreement was 90.7%. For the detection of MRSA, the GeneOhm MRSA PCR was 96.8% sensitive and 86.3% specific, with positive and negative predictive values of 83.9% and 97.3%, respectively. CONCLUSION: Identification of MRSA-colonized patients was achieved in as little as two hours, and the high negative predictive value of GeneOhm MRSA PCR suggests that the assay is a rapid method for the identification of persons who are not colonized with MRSA. However, due to the low positive predictive value, GeneOhm MRSA PCR combined with enrichment culture in cases of positive GeneOhm MRSA PCR is potentially useful for active MRSA surveillance activities.


Assuntos
Humanos , Colo , Meios de Cultura , Seguimentos , Staphylococcus aureus Resistente à Meticilina , Reação em Cadeia da Polimerase , Reação em Cadeia da Polimerase em Tempo Real
15.
The Korean Journal of Laboratory Medicine ; : 18-21, 2011.
Artigo em Inglês | WPRIM | ID: wpr-30867

RESUMO

Monoclonal gammopathy occurs in one-third of the patients with mucosa-associated lymphoid tissue lymphoma (MALT lymphoma). However, monoclonal gammopathy has been rarely reported in Korea. Paraprotenemia accompanying MALT lymphoma is strongly correlated with involvement of the bone marrow, and this involvement leads to the progression of the disease. Here, we present a case of a 66-yr-old man diagnosed with IgM monoclonal gammopathy and stage IV extranodal marginal zone lymphoma of the small intestine, with the involvement of the bone marrow.


Assuntos
Idoso , Humanos , Masculino , Antineoplásicos/uso terapêutico , Medula Óssea/patologia , Quimioterapia Combinada , Eletroforese em Gel de Poliacrilamida , Imunoglobulina M/análise , Neoplasias Intestinais/complicações , Metástase Linfática , Linfoma de Zona Marginal Tipo Células B/complicações , Estadiamento de Neoplasias , Paraproteinemias/sangue , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
16.
Journal of Laboratory Medicine and Quality Assurance ; : 45-68, 2010.
Artigo em Coreano | WPRIM | ID: wpr-96803

RESUMO

The followings are the results for external quality assessment (EQA) in immunoserology for 2009: Evaluation of EQA was done in 2 trials in April and November, about 99% of laboratories participating average 7.4 items. The results were collected via internet and about 98% of laboratories have sent their results via internet. Control materials used in EQA were pooled sera including commercial controls, MASR Immunology Control from Medical Analysis Systems (Camarillo, CA, USA), which were delivered refrigerated for stability of control materials, being received within 48 hours after sending. Latex agglutination tests for rheumatoid factor (RF) showed frequently false positive or false negative results especially in commercial controls, possibly due to matrix effect. False negative and positive results were frequently found in the laboratories using immunochromatography assay (ICA) for anti-HCV and anti-HIV. More careful quality control should be required for ICA tests. New tests measuring non-treponemal and trponemal antibody such as turbidoimmunoassay (TIA) and chemiluminescence immunoassay (CLIA) were introduced. Standardization of instruments and reagents including calibrators for quantitative results should be required for the harmonization of results.


Assuntos
Antígenos de Superfície da Hepatite B , Imunoensaio , Cromatografia de Afinidade , Indicadores e Reagentes , Internet , Coreia (Geográfico) , Testes de Fixação do Látex , Luminescência , Nefelometria e Turbidimetria , Controle de Qualidade , Fator Reumatoide
17.
The Korean Journal of Laboratory Medicine ; : 726-733, 2010.
Artigo em Coreano | WPRIM | ID: wpr-73294

RESUMO

BACKGROUND: Nationwide external quality assessment (EQA) of the fecal occult blood test (FOBT) in Korea was first introduced in 2007-2009. The EQA results were analyzed to assess the current status of FOBT and to plan the continuation of the EQA program. METHODS: The surveys included 40 hospitals in the preliminary survey conducted in 2007, 249 general hospitals in 2008, and 389 hospitals in 2009. In the surveys, the participating hospitals provided the results of the distributed materials and replies to the questionnaire on the FOBT test procedures and quality controls. RESULTS: In the surveys conducted between 2007 and 2009, a total of 650 institutes submitted 653 test system results; 3 institutes used 2 kinds of methods. All of the institutes used immunologic methods; 107 institutes (16.5%) used quantitative equipments and 546 institutes (84.0%) used qualitative kits. Most quantitative tests yielded consistent positive or negative results; however, their cut-off and measured values differed according to the equipments used. A low-level material tested in 2007 was negative in the quantitative methods but positive in some qualitative methods because of lower detection limits. The discordance rates among quantitative tests were 3.2% in 2007, 4.4% in 2008, and 0% in 2009 and the rates among qualitative tests were 13.8% in 2008 and 2.6% in 2009. Semi-solid EQA materials showed the ability to evaluate the overall test procedures with acceptable stability. CONCLUSIONS: In the first Korean FOBT EQA, commercially available EQA materials were proven to be stable. Continuation of the EQA program and further education of laboratory personnel are needed to reduce inconsistency in results. Further, the test kit, procedures, and result reports must be standardized.


Assuntos
Humanos , Neoplasias Colorretais/diagnóstico , Coleta de Dados , Hemoglobinas/análise , Técnicas de Laboratório Clínico/instrumentação , Sangue Oculto , Controle de Qualidade , Inquéritos e Questionários , Kit de Reagentes para Diagnóstico , Temperatura
18.
The Korean Journal of Laboratory Medicine ; : 122-125, 2010.
Artigo em Coreano | WPRIM | ID: wpr-151631

RESUMO

Essential thrombocythemia (ET) is a chronic myeloproliferative neoplasm that involves primarily the megakaryocytic lineage. After many years, a few patients with ET may develop bone marrow (BM) fibrosis and rarely develop osteosclerosis. A 60-yr-old female was admitted due to severe left upper quadrant abdominal discomfort. She had been diagnosed as ET 19 yrs ago. On liver computed tomography severe splenomegaly was shown. Laboratory tests revealed WBC 24.3x10(9)/L, hemoglobin 13.4 g/dL, platelets 432x10(9)/L, lactate dehydrogenase 4,065 IU/L (reference range; 240-480). Blood smear demonstrated leukoerythroblastosis, teardrop cells, and giant and hypogranular platelets. BM study revealed inadequate aspirate due to dry tap. BM biopsy showed clusters of dysplastic megakaryocytes, grade 3 fibrosis, and severe osteosclerosis. Major/minor BCR-ABL1 rearrangement and JAK2 V617F mutation were not detected. Cytogenetic studies revealed normal karyotype. According to the 2008 WHO diagnostic criteria, the patient was diagnosed as having post-essential thrombocythemia myelofibrosis with severe osteosclerosis.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Medula Óssea/patologia , Megacariócitos/patologia , Osteosclerose/complicações , Mielofibrose Primária/complicações , Esplenomegalia/etiologia , Trombocitemia Essencial/complicações , Tomografia Computadorizada por Raios X
19.
The Korean Journal of Laboratory Medicine ; : 559-566, 2010.
Artigo em Coreano | WPRIM | ID: wpr-108485

RESUMO

BACKGROUND: Manual slide review (MSR) is usually triggered by the results of automated hematolgy analyzers, but each laboaratory has different ciriteria for MSR. This study was carried out to investigate the current status of MSR criteria of automated complete blood cell count (CBC) and white blood cell (WBC) differential results and to propose a basic guideline for MSR. METHODS: Total 111 laboratories were surveyed regarding MSR using questionnaires. The questionnaire asked: kinds of automated hematology analyzers used and the presence of criteria triggering MSR in seven categories: 1) CBC results, 2) 5 differential WBC counts, 3) 3 differential WBC counts, 4) automated reticulocyte counts, 5) delta check, 6) instrument flags (or messages), 7) clinical information (wards or diseases). Based on the survey results, we determined basic and extended criteria for MSR. With these criteria, we consulted nine hematology experts to get a consensus. RESULTS: All 111 laboratories had their own MSR criteria. Among 111 laboratories, 98 (88.3%) used more than three criteria for MSR including CBC results and 5-part WBC differential count results and 95 (85.6%) had criteria of flags triggering MSR. For MSR criteria with numeric values, the 10th, 50th, and 90th percentiles of upper and lower threshold values were obtained. The basic guideline for MSR was made. CONCLUSIONS: We proposed a basic guideline for MSR. This guideline would be helpful to hematology laboratories for their daily operation and providing more rapid and accurate CBC and WBC differential results.


Assuntos
Humanos , Automação , Contagem de Células Sanguíneas/instrumentação , Laboratórios Hospitalares , Contagem de Leucócitos/instrumentação , Controle de Qualidade , Inquéritos e Questionários
20.
The Korean Journal of Laboratory Medicine ; : 163-170, 2009.
Artigo em Inglês | WPRIM | ID: wpr-221442

RESUMO

BACKGROUND: The Korean Laboratory Accreditation Program (KLAP) by the Korean Society of Laboratory Medicine (KSLM) was started in 1999. We summarized history and achievement of KLAP for the last 8 yr. METHODS: We analyzed 8 yr data (1999-2006) of historical events, trends of participating laboratories, and scores according to the impact of the question to the outcome of the tests. Inspection check lists are for 'laboratory management', 'clinical chemistry', 'diagnostic hematology', 'clinical microbiology', 'diagnostic immunology', 'transfusion medicine', 'cytogenetics', 'molecular genetics', 'histocompatibility', 'flow cytometry', and 'comprehensive laboratory test verification report'. The laboratories with score 90 or higher got 2-yr certificate and laboratories with score between 60 and 89 got 1-yr certificate. The laboratories with score below 60 failed accreditation. RESULTS: The number of accredited laboratories was 2.4 times higher in 2006 (n=227) than in 1999 (n=96). Inspection check lists have been revised 5 times till 2006. The average accreditation rate was 99.6% during these periods and the 2-yr accreditation rate was 32.4% in 2000, 45.6% in 2001, 53.3% in 2002, 47.3% in 2003, 68.5% in 2004, 37.7% in 2005, and 47.7% in 2006. Number of participants in inspector training workshops increased from 89 in 2000 to 766 in 2006. CONCLUSIONS: The KLAP has been in place successfully and stabilized over the past 8 yr. It seemed to enhance the laboratory quality. Efforts for improvement of quality control and inspector training workshops appeared to be in the main contributing factors.


Assuntos
Acreditação , Educação Médica Continuada , Coreia (Geográfico) , Laboratórios/normas , Patologia Clínica/normas , Avaliação de Programas e Projetos de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA